Low Voltage Electrical Equipment

Low-voltage electrical products
Molded-Case Circuit Breakers (MCCBs)

Molded-Case Circuit Breakers (MCCBs)

  • Engineering-plastic solutions for a broad range of MCCB components.
  • Recommended materials: PA6 and PA66.
  • Housings: A90G25, A90G30, H90GV30, A50G25 and A50G30; all colors available.
  • Shunt-trip device: J60X1V30; all colors available.
Materials for Low-to-Medium Arc-Resistance Requirements

Materials for Low-to-Medium Arc-Resistance Requirements

  • BR2G26WH: glass-fiber-reinforced, nitrogen-based flame-retardant PA6 with a balance of stiffness and toughness for medium arc-resistance requirements.
High-Current Miniature Circuit Breakers

High-Current Miniature Circuit Breakers

  • H90G30: high-temperature PPA with an organophosphorus flame-retardant system and 30% glass fiber.
  • A90G30NC/BK: PA66 with an organophosphorus flame-retardant system and 30% glass fiber.
  • Key requirements: heat resistance, stiffness and GWFI 960°C.
  • Benefits: dimensional stability and halogen-free formulation.
Arc Chutes and Bases

Arc Chutes and Bases

  • Recommended grade: A90G30NC/BK.
  • Key requirements: heat resistance, stiffness, impact performance and injection moldability.
  • Benefits: flame retardancy, low extractables and low corrosion potential.
  • Arc-chute grades: H90G30NC/BK and A90G25NC/BK.
  • Additional benefits: flame retardancy and halogen-free formulation.
Industrial Control Housings

Industrial Control Housings

  • H90G30: high-temperature PPA with an organophosphorus flame-retardant system and 30% glass fiber; RTI 150°C.
  • A90G30NC/BK: PA66 with an organophosphorus flame-retardant system and 30% glass fiber.
  • Key requirements: heat resistance, stiffness, GWFI 960°C, UL 94 V-0, HWI classification above 2 and laser marking.
  • Benefits: flame retardancy and good injection moldability.
Terminal Blocks

Terminal Blocks

  • A80, all colors available: unfilled, halogen-free flame-retardant PA66.
  • C80, all colors available: unfilled, halogen-free flame-retardant PA66/PA6.
  • Key requirements: high flow, flexibility, UL 94 V-0 at 0.4 mm in all colors, and controlled flame and smoke performance.
  • Benefits: short molding cycles and support for up to 50% regrind, subject to validation.
Switches and Plugs

Switches and Plugs

  • Recommended grades: A2NC, B2NC and C80NC.
  • Key requirements: high flow, stiffness and GWFI 850°C.
  • Benefits: good surface appearance and injection moldability.
Coil Bobbins and Supports

Coil Bobbins and Supports

  • Recommended grades: A20G30NC/BK.
  • Key requirements: heat resistance, stiffness and electrical performance.
  • Benefits: flame retardancy and halogen-free formulation.
Circuit Breaker Bases

Circuit Breaker Bases

  • Adjustable glass-fiber content: 10-50%.
  • Excellent creep resistance and RTI above 150°C.
  • Heat deflection temperature up to 270°C, high flow and shorter molding cycles.
  • Suitable for 270°C reflow soldering; stable UL 94 V-0 performance at 0.8 mm.
  • Stable glow-wire performance without flaming.
  • CTI range: 250-350 V.
  • Designed to support UL 746C and IEC 60695 requirements.
  • Recommended grade range: H50G10-50; all colors available.
MCB Internal Structural Components

MCB Internal Structural Components

  • Adjustable glass-fiber content: 10-50%.
  • Excellent creep resistance and RTI above 150°C.
  • Heat deflection temperature up to 270°C, high flow and shorter molding cycles.
  • Suitable for 270°C reflow soldering; stable UL 94 V-0 performance at 0.8 mm.
  • Stable glow-wire performance without flaming.
  • CTI range: 250-350 V.
  • Designed to support UL 746C and IEC 60695 requirements.
  • Recommended grade range: H50G10-50; all colors available.
Magnetic Contactors

Magnetic Contactors

  • Recommended grades: H90G30NC/BK and A90G25NC/BK.
  • Key requirements: heat resistance and stiffness.
  • Benefits: flame retardancy, halogen-free formulation and broad color availability.
Materials for Medium-to-High Arc-Resistance Requirements

Materials for Medium-to-High Arc-Resistance Requirements

  • B90G30: glass-fiber-reinforced PA6 with an organophosphorus flame-retardant system, optimized for electrical performance and injection molding.
  • A90G25/30: glass-fiber-reinforced PA66 with an organophosphorus flame-retardant system, heat resistance and reduced moisture uptake.
  • H90G30: high-temperature, glass-fiber-reinforced polyamide with an organophosphorus flame-retardant system, heat resistance and reduced moisture uptake.
Low-Current Miniature Circuit Breakers

Low-Current Miniature Circuit Breakers

  • BR2G26WH: halogen-free flame-retardant PA6 with 30% glass fiber.
  • Key requirements: heat resistance, injection moldability and GWFI 960°C.
  • Benefits: arc resistance and low extractables.
MCCB Housings and Structural Parts

MCCB Housings and Structural Parts

  • Material: glass-fiber-reinforced, brominated flame-retardant PPA.
  • Adjustable glass-fiber content: 10-50%.
  • Excellent creep resistance and RTI above 150°C.
  • Heat deflection temperature up to 270°C, high flow and shorter molding cycles.
  • Suitable for 270°C reflow soldering; stable UL 94 V-0 performance at 0.8 mm.
  • Stable glow-wire performance without flaming.
  • CTI range: 250-350 V.
  • Designed to support UL 746C and IEC 60695 requirements.
  • Recommended grade range: H50G10-50; all colors available.
Moving Contact Carriers

Moving Contact Carriers

  • Thermoplastic alternative to selected thermoset materials.
  • Adjustable glass-fiber content: 10-50%.
  • Custom colors and laser-marking capability; RTI above 150°C.
  • Heat deflection temperature up to 270°C, high flow and shorter molding cycles.
  • Suitable for 270°C reflow soldering; stable UL 94 V-0 performance at 0.8 mm.
  • Halogen- and red-phosphorus-free; designed for WEEE and RoHS compliance.
  • Designed to support UL 746C and IEC 60695 requirements.
  • High CTI range: 550-600 V and strong arc resistance.
  • Recommended grade range: H90G10-50; all colors available.

Not sure which grade fits your part? Send us the part drawing and requirements.

Send your requirements
Scroll to Top